CHLED

Striplight

Click to download

Click to download

Description

The CHLED series of low profile, open LED striplights provides superior energy efficiency and a longer, maintenance-free operating life over the traditional T5 and T8 fluorescent fixtures they are designed to replace.

Using up to 54% less energy and operating for up to 72,000 hours (L70), the CHLED LED striplights are ideal for uplight and downlight in commercial, manufacturing, and warehouse applications.

CHLED is available in 2’, 4’, and 8’ lengths with a choice of 10 lumen packages in 3 color temperatures.

UPGRADE YOUR LIGHTING WITH LED

Whether you’re adding new lighting or replacing existing outdated lighting, Simkar’s CHLED LED striplights provide excellent illumination, performance, and durability.

SUPERIOR PERFORMANCE

The CHLED Series offers a familiar form with exceptional performance.

Used any place a traditional fluorescent strip would be found, the CHLED offers a wide range of lumen outputs in three color temperatures.

LONG-TERM RELIABILITY AND OPERATION

Up to a 72,000 hour operating life (L70) lets you install the fixtures and expect over 16 years of LED operating life.

EXPANDED OPERATION

Also offered are options for mounting, emergency lighting, and controls, greatly extending the range of applications that are ideal for the CHLED.

Configuration

CHLED Configuration

CHLED2 = 2′

4 = 4′

8 = 8′

2′ Units

25 = 2500 lm (20W)

30 = 3000 lm (25W)

4′ Units

25 = 2500 lm (20W)

50 = 5000 lm (36W)

70 = 7000 lm (55W)

95 = 9500 lm (73W)

8′ Units

55 = 5500 lm (40W)

100 = 10,000 lm (72W)

150 = 15,000 lm (110W)

200 = 20,000 lm (146W)

35 = 3500˚K

40 = 4000˚K

50 = 5000˚K

U1 =
Universal 120-277V347 = 347V480 = 480V
ELS = Emergency Backup, 900lm

6’ Cord and Plug

CPT(x)

1 = 120V

2 = 277V

3 = 208V

4 = 240V

5 = 480V

CP3 =
Cord & Plug-120V Straight Blade 5-15P

FL6 =
3/8” Flex with two connectors

FL7 =
3/8” Flex with two connectors; for dual switching or ELS

Sensors (factory wired; see switching; for daylight harvesting, please contact factory)

OS(x)* =
PIR Occupancy sensor
(specify # of drivers controlled (1 or 2)

OSPC(x) =
PIR Occupancy sensor with photocontrol
(specify # of drivers controlled (1 or 2)

Reflectors

SRW =
White

C =
Single white canopy (for use with pendant mount)CA24 =
Chain Hanger Assembly-(2) 18” chains, (2) “V” hooks, (2) “S” hooks for total drop 24”CHJ = Housing Joiner (for continuous runs)CS24 = “S” Hook (4) Chain Hanger Assembly (24” total drop)PM2(x) =
Pendant Mount, white stem-specify length in inches (24, 36, 48, 60, 72)SN = Snapper BracketsTBH = T-Bar grid mounting clipWG220 = 24” wire guard (order 2 for 8′ units; (not available with SRW option)

WG240 = 48” wire guard (order 2 for 8′ units; (not available with SRW option)

Asymmetric Reflectors

AR(x)20 = 24″

AR(x)30 = 36” (Order 2 for tandem 72” units)

AR(x)40 = 48” (Order 2 for tandem 96” units)

For (x) enter (W) for white or (S) for specular aluminum

* Nominal. See performance tables for actual input power.

Performance

CHLED Performance – 4100K CCT

Model LengthLumens* Input PowerDriversEfficacyEquivalent Fluorescent**
CHLED22535U12′2,53519.58W1 28W 750mA129.5 lm/W2 17W T8, 1 24W T5HO
CHLED22540U12′2,66420.47W1 28W 750mA130 lm/W2 17W T8, 1 24W T5HO
CHLED22550U12′2,77020.47W1 28W 750mA135 lm/W2 17W T8, 1 24W T5HO
CHLED23035U12′3,03125W1 40W 1A120 lm/W2 17W T8, 1 24W T5HO
CHLED23040U12′3,12525W1 40W 1A125 lm/W2 17W T8, 1 24W T5HO
CHLED23050U12′3,25025W1 40W 1A130 lm/W2 17W T8, 1 24W T5HO
CHLED42535U14′2,58720.47W1 28W 750mA126.4 lm/W1 32W T8
CHLED42540U14′2,66420.47W1 28W 750mA126.4 lm/W1 32W T8
CHLED42550U14′2,77020.47W1 28W 750mA135 lm/W1 32W T8
CHLED45035U14′4,88636.59W1 50W 1.4A133.53 lm/W2 32W T8, 1 54W T5HO
CHLED45040U14′4,92836.36W1 50W 1.4A135.5 lm/W2 32W T8, 1 54W T5HO
CHLED45050U14′5,15636.84W1 50W 1.4A140 lm/W2 32W T8, 1 54W T5HO
CHLED47035U14′6,96055.38W1 60W 2.1A125.7 lm/W2-32W T8, 2-54W T5HO
CHLED47040U14′7,16055.38W1 60W 2.1A129.28 lm/W2-32W T8, 2-54W T5HO
CHLED47050U14′7,44655.38W1 60W 2.1A134.45 lm/W2-32W T8, 2-54W T5HO
CHLED49535U14′9,41973.15W2 50W 1.4A128.8 lm/W2-54W T5HO
CHLED49540U14′9,70173.15W2 50W 1.4A132.61 lm/W2-54W T5HO
CHLED49550U14′10,08973.15W2 50W 1.4A138 lm/W2-54W T5HO
CHLED85535U18′5,17440.94W2 28W 750mA126.38 lm/W2 32W T8
CHLED85540U18′5,32840.94W2 28W 750mA130.14 lm/W2 32W T8
CHLED85550U18′5,54140.94W2 28W 750mA135.34 lm/W2 32W T8
CHLED810035U18′9,73272.72W2 50W 1.4A133.8 lm/W2 32W T8, 2 54W T5HO
CHLED810040U18′9,85672.72W2 50W 1.4A135.53 lm/W2 32W T8, 2 54W T5HO
CHLED810050U18′10,31272.72W2 50W 1.4A141.8 lm/W2 32W T8, 2 54W T5HO
CHLED815035U18′13,920110.76W2 60W 2.1A125.67 lm/W4-32W T8
CHLED815040U18′14,320110.76W2 60W 2.1A129.28 lm/W4-32W T8
CHLED815050U18′14,892110.76W2 60W 2.1A135 lm/W4-32W T8
CHLED820035U18′18,838146.3W4 50W 1.4A128.76 lm/W4 54W T5HO
CHLED820040U18′19,402146.3W4 50W 1.4A132.6 lm/W4 54W T5HO
CHLED820050U18′20,178146.3W4 50W 1.4A137.92 lm/W4 54W T5HO

*Delivered lumens **Consult a lighting engineer to meet specific requirements.

Specifications

Specifications

HOUSING Housing, wireway cover and ends are die-formed heavy gauge steel with high gloss, baked white enamel finish over rust inhibiting phosphate coat. Housing and wireway cover act as heat sink to dissipate heat, maximizing the life of the LEDs and power supplies. Knockouts provided on back, ends, and sides. Reflectors available.

LEDs 2’ Fixtures available in 2 light levels (delivered); 2664 lumens (20.47W) and 3125 lumens (25W) at 4000K CCT, >80 CRI. 4’ Fixtures available in 4 light levels (delivered); 2664 lumens (20.5W), 4928 lumens (36.4W), 7160 lumens (55.4W) and 9701 lumens (73.2W) at 4000K CCT, >80 CRI. 8’ Fixtures available in 4 light levels (delivered); 5328 lumens (41W), 9,856 lumens (72.7W), 14,320 lumens (110.8W), and 19,402 lumens (146.3W) at 4000K CCT, >80 CRI. All models also available in 3500K and 5000K color temperatures. Beam spread is 110 degrees. LEDs are LM-80 tested. Operating life is 72,000 hours (L70). Replaceable Light engines consist of 48, 96, 192, or 384 mid-power LED chips mounted on aluminum core printed circuit boards.

ELECTRICAL 120-277V LED power supply, power factor is >0.9. 0-10V dimmable, standard. Power supplies are mounted in direct contact with steel housing for cooler operation and longer life. Drive current is 750mA for units using 28W drivers. Drive current is 1.4A for units using 40W and 50W drivers. Drive current is 2.1A units using 60W drivers. Power supplies are field replaceable. See performance table for number of drivers in each unit.

Temperature The CHLED series is designed to operate in temperatures of -13˚F (-25˚C) to 104˚F (40˚C).

ACCESS / WIRING Toolless access to wireway striplight. Wireway cover/LED tray snaps onto the housing and can be removed without tools. LED tray can be secured to housing with screws (optional). Wireway cover/LED tray includes tethers (4’ and 8’ units) for easier installation and maintenance. Internal plug-in wiring harness.

MOUNTING Suitable for surface, pendant, stem, or chain mounting, individually or in continuous rows. Use accessory CHJ joiner for continuous rows.

LISTINGS UL listed, damp location. DesignLights™ Consortium Listed direct linear ambient, low bay, and high bay.

WARRANTY 5 year limited warranty.

Photometrics

Photometrics / IES files

Contact Simkar about CHLED

  • This field is for validation purposes and should be left unchanged.

Share this product